52
Participants
Start Date
January 31, 2013
Primary Completion Date
December 31, 2017
Study Completion Date
December 31, 2018
real Repetitive Transcranial Magnetic Stimulation
The rTMS treatments were performed using a Medtronic MagPro type magnetic stimulation device (Medtronic, Minneapolis, MN, USA) and a figure-of-eight coil (MC-B70, Medtronic). Coils were placed tangent to the scalp. The stimulation protocol involved 50 trains of 20 pulses applied over the ipsilesional M1 at a frequency of 5 HZ, with the stimulus intensity set at 120% of the resting motor threshold of the unaffected extremity.
sham Repetitive Transcranial Magnetic Stimulation
The sham rTMS was performed on the same site as the rTMS treatment group but without any true stimulations. Coils were placed perpendicular to the scalp.
Peking Union Medical College Hospital, Beijing
Collaborators (1)
Chinese Academy of Sciences
OTHER_GOV
University of Pennsylvania
OTHER
Peking Union Medical College Hospital
OTHER