Comparison of Pattern Recognition Control and Direct Control in TMR

NACompletedINTERVENTIONAL
Enrollment

11

Participants

Timeline

Start Date

June 30, 2013

Primary Completion Date

September 29, 2017

Study Completion Date

September 29, 2017

Conditions
AmputationAmputation; Traumatic, Arm, Upper
Interventions
DEVICE

Commercial system

Transhumeral amputees who have had TMR will use a commercially available prosthesis with an elbow,wrist, and a hand with custom electronics and software for both direct and pattern recognition - based control.

DEVICE

RIC arm system

Transhumeral amputees who have had TMR will use the RIC arm system prosthesis with an elbow,wrist, and a hand with custom electronics and software for both direct and pattern recognition - based control.

OTHER

Direct Control

Transhumeral amputees who have had TMR will use either a commercially available prosthesis or the RIC arm system prosthesis with an elbow,wrist, and a hand with custom electronics and software for both direct control.

OTHER

Pattern Recognition

Transhumeral amputees who have had TMR will use either a commercially available prosthesis or the RIC arm system prosthesis with an elbow,wrist, and a hand with custom electronics and software for pattern recognition control.

Trial Locations (1)

60611

Rehabilitation Institute of Chicago, Chicago

All Listed Sponsors
collaborator

United States Department of Defense

FED

lead

Shirley Ryan AbilityLab

OTHER

NCT03097978 - Comparison of Pattern Recognition Control and Direct Control in TMR | Biotech Hunter | Biotech Hunter