135
Participants
Start Date
June 30, 2014
Primary Completion Date
June 30, 2015
Study Completion Date
June 30, 2015
Standard shock waves device
3 sessions were applied: one per week. Energy flux density 0,18 mJ/mm2. Frequency: 8 Hz. 2500 shockwaves/session. The shock waves emitted to the 3 devices are identical; the only difference is the external image of the device.
Austere shock waves device
3 sessions were applied: one per week. Energy flux density 0,18 mJ/mm2. Frequency: 8 Hz. 2500 shockwaves/session. The shock waves emitted to the 3 devices are identical; the only difference is the external image of the device.
Sophisticated shock waves device
3 sessions were applied: one per week. Energy flux density 0,18 mJ/mm2. Frequency: 8 Hz. 2500 shockwaves/session. The shock waves emitted to the 3 devices are identical; the only difference is the external image of the device.
"Rehabilitation Center Salut i Esport", Santa Perpètua de Gaià
Asociacion Colaboracion Cochrane Iberoamericana
OTHER