Ultrasound Versus Palpation for Epidural Catheterization

NACompletedINTERVENTIONAL
Enrollment

110

Participants

Timeline

Start Date

April 30, 2015

Primary Completion Date

September 30, 2015

Study Completion Date

September 30, 2015

Conditions
Epidural AnesthesiaSpinal Ultrasound
Interventions
PROCEDURE

Double-space combined spinal-epidural anesthesia

Epidural space identification in Lumbar 2-3 or 3-4 space using loss of resistance to air technique with 18-gauge Tuohy needle, then threading a 20-gauge multi-orifice epidural catheter 4-5 cm into the epidural space. Spinal anesthesia administration in an appropriate lower intervertebral space with intrathecal bupivacaine 12.5 mg and fentanyl 10 mcg through a 27-gauge spinal needle.

RADIATION

Preprocedure spinal ultrasound

Lumbar spinal ultrasound using the 2-5 MHz curved probe, performed in both the longitudinal and transverse planes for identification of the appropriate intervertebral spce, estimation of the depth to the epidural space, and noting the proper angle for subsequent needle insertion. Then skin markings relying on the ultrasound procedure are made identifying 2 intervertebral spaces.

RADIATION

Sham ultrasound procedure

Applying the ultrasound probe on the patient's back while the ultrasound machine is on the freeze position.Then skin markings relying on landmark palpation are made identifying 2 intervertebral spaces.

Trial Locations (1)

35511

Department of Anesthesia, Mansoura University Hospitals, Al Mansurah

All Listed Sponsors
lead

Mansoura University

OTHER