Auriculotherapy for Osteoarthritis Knee

PHASE3CompletedINTERVENTIONAL
Enrollment

44

Participants

Timeline

Start Date

January 31, 2015

Primary Completion Date

June 30, 2016

Study Completion Date

June 30, 2016

Conditions
Knee Osteoarthritis
Interventions
OTHER

magnetotherapy

The magnetic pellets will contain an average of \~200 gauss/pellet magnetic flux densities, with a diameter of 1.76 mm

DEVICE

laser auriculotherapy

A laser device (pointer pulse) will be used in this study. This device has a wavelength of 650 nm, an average output power of 2.5 mW, energy density of 1 minute with 0.54 J/cm2, and a pulse of 10 Hz, which is a common acceptable dosage for clinical use. This application belongs to a low-energy laser therapy (LLLT), in which the energy level emitted from the device is approximately comparable to a teaching pointer.

OTHER

Placebo

"Subjects will serve as a placebo control, and will receive LAT at power off mode (i.e. deactivated laser) for acupoint stimulation before the application of plaster without magnetic pellets that mimic MAT treatment."