40
Participants
Start Date
June 30, 2014
Primary Completion Date
August 31, 2015
Study Completion Date
August 31, 2015
ETT cleaning maneuver
"EndOclear is a commercially available device. It consists of an endotracheal tube cleaning apparatus with a flexible central tube and a cleaning device at its distal end. In operation, the collapsed cleaning apparatus is inserted into the ETT through a Y-shaped connector. The device is then expanded by a safety toggle protected trigger mechanism that, when fired, presses the device's smooth silicone disc against the inside surface of the endotracheal tube. The cleaning apparatus is then pulled out of the endotracheal tube removing mucus deposits and secretions.~We plan to add the use of endOclear to the standard ICU practice, scheduling the systematic use of the device every 8 hours for the whole intubation period."
Massachusetts General Hospital, Boston
Brigham and Women's Hospital
OTHER
Rhode Island Hospital
OTHER
Massachusetts General Hospital
OTHER