Effects of Hemodynamic Monitoring Using the ImaCor Single Use Transesophageal Echocardiography Probe in Critically Ill Patients

NACompletedINTERVENTIONAL
Enrollment

550

Participants

Timeline

Start Date

March 31, 2014

Primary Completion Date

October 19, 2017

Study Completion Date

May 1, 2018

Conditions
Shock
Interventions
DEVICE

ImaCor PM

The ImaCor ClariTEE (hTEE) device is a transesophageal echocardiography system. It produces a single-plane two-dimensional image. The ImaCor probe is a 5.5 mm detachable probe; it can remain in situ for up to 72h and allows for reassessment of the patient's hemodynamic progress and the effect of selected interventions at any time. The probe is connected to a dedicated echocardiographic system which allows the for the recording of digital loops and performance of basic two-dimensional measurements. ImaCorPM subjects will receive echocardiography-guided hemodynamic management (hTEE) at the time of inclusion, at the time of occurrence of defined new organ system deterioration and/or at least every 4 hours during the first 72h after study inclusion or until one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.

DEVICE

ImaCor SM

The ImaCor ClariTEE (hTEE) device is a transesophageal echocardiography system. It produces a single-plane two-dimensional image. The ImaCor probe is a 5.5 mm detachable probe; it can remain in situ for up to 72h and allows for reassessment of the patient's hemodynamic progress and the effect of selected interventions at any time. The probe is connected to a dedicated echocardiographic system which allows the for the recording of digital loops and performance of basic two-dimensional measurements. ImaCorSM subjects will receive echocardiography-guided hemodynamic management (hTEE) at the time of inclusion, follow-up assessment intervals are at the discretion of the treating physician for the first 72h after study inclusion. hTEE monitoring is discontinued if one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.

OTHER

Control PM

Group Control protocolized monitoring (ControlPM) will receive any hemodynamic monitoring of choice of the treating physician except ImaCor. Protocolized hemodynamic assessments will be performed at the time of inclusion, at the time of occurrence of defined new organ system deterioration or at least every 4 hours for the first 72h after study inclusion. Protocolized monitoring is discontinued if one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.

OTHER

Control SM

Group Control standard monitoring (ControlSM) will receive any hemodynamic monitoring of choice of the treating physician except ImaCor. Protocolized hemodynamic assessments will be performed at the time of inclusion, follow-up measurement intervals are at the discretion of the treating physician for the first 72h. Data collection from standard monitoring is discontinued if one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.

Trial Locations (1)

3010

Dep. of Intensive Care Medicine, Bern University Hospital, Bern

All Listed Sponsors
collaborator

ImaCor, Inc.

INDUSTRY

lead

Insel Gruppe AG, University Hospital Bern

OTHER