568
Participants
Start Date
October 31, 2013
Primary Completion Date
October 31, 2017
Study Completion Date
October 31, 2017
IVUS guided percutaneous coronary angioplasty with Resolute integrity stent insertion
Resolute integrity stent implantation (diameter from 2.5mm to 3.5mm, length 30, 34, 38mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. IVUS will be used to assess the anatomic characteristics of lesion and determine appropriate stent size and length. Additional stent implantation or post dilation will be allowed according to attending physician's discrete based on IVUS results.
Angiography guided percutaneous coronary angioplasty with Resolute integrity stent insertion
Resolute integrity stent implantation (diameter from 2.5mm to 3.5mm, length 30, 34, 38mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. Additional stent implantation or post dilation will be allowed according to attending physician's discrete. IVUS will be not used in this arm.
Angiography guided percutaneous coronary angioplasty with Promus element stent implantation
Promus element stent implantation (diameter from 2.5mm to 3.5mm, length 28, 32, 36mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. Additional stent implantation or post dilation will be allowed according to attending physician's discrete. IVUS will be not used in this arm.
Angiography guided percutaneous coronary angioplasty with Promus element stent implantation
Promus element stent implantation (diameter from 2.5mm to 3.5mm, length 28, 32, 36mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. IVUS will be used to assess the anatomic characteristics of lesion and determine appropriate stent size and length. Additional stent implantation or post dilation will be allowed according to attending physician's discrete based on IVUS results.
Division of Cardiology, Yonsei Cardiovascular Hospital, Yonsei University College of Medicine, Seoul
Yonsei University
OTHER