Intravascular ULTrasound Guided Versus Conventional Angiography Guided Strategy to Deploy Zotarolimus and Everolimus Eluting Third Generation Stents in the Long Coronary Artery Lesions: ULTRA-ZET Trial

NACompletedINTERVENTIONAL
Enrollment

568

Participants

Timeline

Start Date

October 31, 2013

Primary Completion Date

October 31, 2017

Study Completion Date

October 31, 2017

Conditions
Coronary Artery Disease
Interventions
PROCEDURE

IVUS guided percutaneous coronary angioplasty with Resolute integrity stent insertion

Resolute integrity stent implantation (diameter from 2.5mm to 3.5mm, length 30, 34, 38mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. IVUS will be used to assess the anatomic characteristics of lesion and determine appropriate stent size and length. Additional stent implantation or post dilation will be allowed according to attending physician's discrete based on IVUS results.

DEVICE

Angiography guided percutaneous coronary angioplasty with Resolute integrity stent insertion

Resolute integrity stent implantation (diameter from 2.5mm to 3.5mm, length 30, 34, 38mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. Additional stent implantation or post dilation will be allowed according to attending physician's discrete. IVUS will be not used in this arm.

DEVICE

Angiography guided percutaneous coronary angioplasty with Promus element stent implantation

Promus element stent implantation (diameter from 2.5mm to 3.5mm, length 28, 32, 36mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. Additional stent implantation or post dilation will be allowed according to attending physician's discrete. IVUS will be not used in this arm.

PROCEDURE

Angiography guided percutaneous coronary angioplasty with Promus element stent implantation

Promus element stent implantation (diameter from 2.5mm to 3.5mm, length 28, 32, 36mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. IVUS will be used to assess the anatomic characteristics of lesion and determine appropriate stent size and length. Additional stent implantation or post dilation will be allowed according to attending physician's discrete based on IVUS results.

Trial Locations (1)

120-752

Division of Cardiology, Yonsei Cardiovascular Hospital, Yonsei University College of Medicine, Seoul

All Listed Sponsors
lead

Yonsei University

OTHER

NCT01979744 - Intravascular ULTrasound Guided Versus Conventional Angiography Guided Strategy to Deploy Zotarolimus and Everolimus Eluting Third Generation Stents in the Long Coronary Artery Lesions: ULTRA-ZET Trial | Biotech Hunter | Biotech Hunter