tDCS
"Intelect mobile combination (Intelect, USA) is utilized as a direct current stimulator. The 25 cm2 electrodes on a sponge slice immersed in physiological salt solution are fixed on the left and right positions C3/ C4 of subject head (according to the international 10-20 system of electroencephalogram).~During the treatment, 1.5 mA electric current is applied to stimulate the subjects in the experimental group for totally 30 minutes. At the start and the end of stimulation, the electric current will gradually increase from zero, or reduce to zero in 1 minute in order to avoid the possible appearance of slight flash effect of subject eyesight, which is caused by instantly turning on or turning off the electric current."
Epidermis anesthesia
"15 g of Emla 5% Cream(anesthetic) is applied to the ventral surface of the forearm of unaffected side with a distance of 10 mm from the wrist, and an area of 150 mm long x 50 mm wide.~Furthermore, 10 g Emla 5% Cream(anesthetic) is applied to the ventral surface of the upper arm of affected side with a distance of 10 mm from the wrist, and an area of 100 mm long x 50 mm wide."
sham anesthesia
"15 g of 5% body Cream is applied to the ventral surface of the forearm of unaffected side with a distance of 10 mm from the wrist, and an area of 150 mm long x 50 mm wide.~10 g body Cream is applied to the ventral surface of the upper arm of affected side with a distance of 10 mm from the wrist, and an area of 100 mm long x 50 mm wide."
Repeated passive movement
"Repeated passive wrist extension training: Patients' wrist joint are passively moved by a trained occupational therapist (joint moving angle = 0- 60 degree), frequency 1 Hz, maintain for 20 minutes.~Finger passive flexion and extension training: Patients' fingers joint are passively moved by a trained occupational therapist, frequency 1 Hz, maintain for 10 minutes."
sham tDCS
The equipment of sham stimulation in the control group is exactly the same as the equipment in the experiment group. However, the only difference is that 30 seconds after the start of electric current, the experimenter turns off the powder under subject ignorance situation. The stimulation just gives patients weak sense of electric current, in order to blind them for which group they are in.