Noninvasive ventilation
Bilevel positive pressure (BiPAP Synchrony, Respironics®, Murrysville, Pennsylvania, USA) was applied through face mask (Comfort Full 2, Respironics®, Murrysville, Pennsylvania, USA) attached with straps and pressure adjusted were 12 cmH2O of inspiratory pressure and 5 cmH2O of expiratory pressure at the beginning of the procedure (França et al., 2006).
Jet nebulizer
"Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. JN (Mist yMax, Air Life, Yorba Linda, USA) was positioned in the circuit using a T piece, particle size generation in a 5 µm range (according to the manufacturer information) and flow oxygen tritated at 8 L/min."
The vibrating mesh nebulizer (VMN)
Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. VMN (Aeroneb Solo, Galway, Ireland) was positioned in the mask using an elbow (Elbow Kit, Respironics®, Murrysville, Pennsylvania, USA), particle size generation in a 1 µm and connected to electrical energy.