Efficacy and Safety of Heparin-grafted Membrane for CRRT

NACompletedINTERVENTIONAL
Enrollment

20

Participants

Timeline

Start Date

August 31, 2013

Primary Completion Date

December 31, 2016

Study Completion Date

December 31, 2016

Conditions
Acute Kidney InjuryHemorrhageCoagulopathy
Interventions
DEVICE

oXiris as first filter

2 arms - each start off CRRT with either oXiris or M150 as first hemofilter, and then do cross-over to either hemofilters in a sequential manner when the former clots

DEVICE

M150 as first filter

start off with M150 as first hemofilter, then cross-over to oXiris when former clots, and then to M150, and then lastly to oXiris